Modular Heatless Desiccant Dryers 5-300 m3/h (3-176 SCFM)

Our innovative modular desiccant dryers are compact, fully integrated units ideal at point-of-use, so you only pay to dry the air required for your operation. The dryers deliver ISO Class 2 dew point performance, with optional ISO Class 1 to help prevent corrosion, minimize production disruptions and losses due to moisture or contamination. Easy on-site maintenance puts your production line back on line quickly.
High Air Quality: High-performance desiccant technology delivers ISO Class 2 or Class 1 pressure dew point air for critical applications; high efficiency pre-filter and general Purpose after-filter protect desiccant and downstream air from oil contamination and particulates.


Reliable Operation: High-strength desiccant, durable valves and components and long cycles extend equipment life.


Reduced Energy Use: Low pressure drop design saves on energy costs and provides an economical drying solution. Energy Management System option for further energy use reduction.


State-of-the-Art Control: Easy to use, advanced microprocessor with visual display showing data in real time to maintain dryer performance at optimum levels, providing preventative maintenance alerts as well as protection notifications for efficiency and connectivity.


Easy Installation and Maintenance: With a compact footprint and low noise operation, modular dryers are suitable to be quickly installed right in the work environment and easy maintained, with preventative maintenance alerts

Drying process
  1. Compressed air stream with moisture enters the dryer from inlet valve, depending where the PLC sequence step is, this will be either the left or right column
  2. The compressed air gets dried going upward in the column through the desiccant media that adsorb water vapor
  3. From the exit valve, the dried air is delivered to the air system
Regenerating process
  1. Simultaneously to drying the compressed air in the other column, a limited amount of dried air is passed from the upper outlet valve and expanded to atmospheric pressure through purge orifice housed within the valve, to the regenerating column
  2. This regeneration air flows downwards through the saturated desiccant of the other column and regenerates the desiccant by  adsorbing the moisture  
  3. The expanded regeneration air containing the adsorbed moisture is discharged through the exhaust solenoid valve and muffler
  4. The sphere in the valve and its position, right or left, determines which column is drying and regenerating. The movement of the  sphere is driven by the pressure difference between the columns (pressure for drying column and atmospheric pressure for  regenerating column) driven by exhaust solenoid valves in the bottom part of the dryers      

CCN

Description

Capacity (m3/h/SCFM)

Max Operating Pressure BarG (psig)

Pressure Dew Point °C (°F)

Air in/out connection BSP (in)

Dimensions [W x D x H (mm) x Weight (kg)]

Power Supply (Volt/ph/Hz)

Desiccant per tower Kg (lb)

47675073001

DA5IM -40°F

5 (3)

14 (203)

-40 (-40)

(3/8")

238 x 212 x 423 x 11

115/1/60

0.7 (1.5)

47675074001

DA15IM -40°F

15 (9)

14 (203)

-40 (-40)

(3/8")

238 x 212 x 823 x 18

115/1/60

2.2 (4.7)

47675075001

DA25IM -40°F

25 (15)

14 (203)

-40 (-40)

(3/8")

238 x 212 x 1073 x 27

115/1/60

3.0 (6.6)

47675076001

DA40IM -40°F

40 (24)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 968 x 44

115/1/60

6.4 (14.1)

47675077001

DA55IM -40°F

55 (32)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 1118 x 50

115/1/60

8.4 (18.4)

47675078001

DA70IM -40°F

70 (41)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 1318 x 60

115/1/60

10.9 (24.0)

47675079001

DA100IM -40°F

100 (59)

14 (203)

-40 (-40)

(1")

475 x 405 x 1673 x 73

115/1/60

15.4 (33.9)

47675080001

DA150IM -40°F

150 (88)

14 (203)

-40 (-40)

(1")

475 x 405 x 1873 x 90

115/1/60

18.0 (39.6)

47675081001

DA200IM -40°F

200 (118)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1705 x 177

115/1/60

30.8 (67.9)

47675082001

DA250IM -40°F

250 (147)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1905 x 180

115/1/60

35.9 (79.1)

47675083001

DA300IM -40°F

300 (177)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1905 x 188

115/1/60

35.9 (79.1)

47677658001

DA40IM -40°F EMS

40 (24)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 968 x 44

115/1/60

6.4 (14.1)

47677659001

DA55IM -40°F EMS

55 (32)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 1118 x 50

115/1/60

8.4 (18.4)

47677660001

DA70IM -40°F EMS

70 (41)

14 (203)

-40 (-40)

(3/4")

475 x 405 x 1318 x 60

115/1/60

10.9 (24.0)

47677661001

DA100IM -40°F EMS

100 (59)

14 (203)

-40 (-40)

(1")

475 x 405 x 1673 x 73

115/1/60

15.4 (33.9)

47677662001

DA150IM -40°F EMS

150 (88)

14 (203)

-40 (-40)

(1")

475 x 405 x 1873 x 90

115/1/60

18.0 (39.6)

47677663001

DA200IM -40°F EMS

200 (118)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1705 x 177

115/1/60

30.8 (67.9)

47677664001

DA250IM -40°F EMS

250 (147)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1905 x 180

115/1/60

35.9 (79.1)

47677665001

DA300IM -40°F EMS

300 (177)

14 (203)

-40 (-40)

(1 1/2")

536 x 495 x 1905 x 188

115/1/60

35.9 (79.1)

47759137001

DA5IM -100°F

4 (2)

14 (203)

-70 (-100)

(3/8")

238 x 212 x 423 x 11

230/1/50-60

0.7 (1.5)

47759138001

DA40IM -100°F

12 (7)

14 (203)

-70 (-100)

(3/8")

238 x 212 x 823 x 18

230/1/50-60

2.2 (4.7)

47759139001

DA15IM -100°F

20 (12)

14 (203)

-70 (-100)

(3/8")

238 x 212 x 1073 x 27

230/1/50-60

3 (6.6)

47677702001

DA25IM -100°F

32 (19)

14 (203)

-70 (-100)

(3/4")

475 x 405 x 968 x 44

115/1/60

6.4 (14.1)

47677703001

DA55IM -100°F

44 (26)

14 (203)

-70 (-100)

(3/4")

475 x 405 x 1118 x 50

115/1/60

8.4 (18.4)

47677704001

DA70IM -100°F

56 (33)

14 (203)

-70 (-100)

(3/4")

475 x 405 x 1318 x 60

115/1/60

10.9 (24.0)

47677705001

DA100IM -100°F

80 (47)

14 (203)

-70 (-100)

(1")

475 x 405 x 1673 x 73

115/1/60

15.4 (33.9)

47677706001

DA150IM -100°F

120 (71)

14 (203)

-70 (-100)

(1")

475 x 405 x 1873 x 90

115/1/60

18.0 (39.6)

47677707001

DA200IM -100°F

160 (94)

14 (203)

-70 (-100)

(1 1/2")

536 x 495 x 1705 x 177

115/1/60

30.8 (67.9)

47677708001

DA250IM -100°F

200 (118)

14 (203)

-70 (-100)

(1 1/2")

536 x 495 x 1905 x 180

115/1/60

35.9 (79.1)

47677709001

DA300IM -100°F

240 (141)

14 (203)

-70 (-100)

(1 1/2")

536 x 495 x 1905 x 188

115/1/60

35.9 (79.1)